An error occurred on this page.
These results could be incomplete or invalid. Staff have been notified.



Project measure / variable:   Gould2   FC_immediate_acu_09


  STRAIN COMPARISON PLOT
Dimensions Width:   px    Height:   px
Download Plot   
Visualization Options

Gould2 - acute group, percent immobility in training chamber after first stimulus pairing dose 0.09 mg



  MEASURE SUMMARY
Measure Summary Male
Number of strains tested8 strains
Mean of the strain means13.8   %
Median of the strain means8.62   %
SD of the strain means± 15.4
Coefficient of variation (CV)1.12
Min–max range of strain means0   –   42.5   %
Mean sample size per strain10.5   mice


  ANOVA, Q-Q NORMALITY ASSESSMENT
ANOVA summary      
FactorDFSum of squaresMean sum of squaresF valuep value (Pr>F)
strain 7 16759.125 2394.1607 26.8673 < 0.0001
Residuals 76 6772.3954 89.1105


Q-Q normality assessment based on residuals

  


  STRAIN MEANS (UNADJUSTED)
  
Select table page:
Strain Sex Mean SD N mice SEM CV Min, Max Z score
129S6/SvEvTac m 29.2 8.08   10 2.56 0.277 16.7, 41.7 1.0
A/J m 13.9 9.32   9 3.11 0.671 0.01
BALB/cByJ m 1.66 3.5   10 1.11 2.11 -0.79
C3H/HeJ m 3.33 5.83   10 1.84 1.75 -0.68
C57BL/6J m 1.92 5.0   13 1.39 2.6 -0.77
CBA/J m 0.0 0.0   8 0.0 0.0 -0.89
DBA/1J m 17.9 13.4   14 3.59 0.752 0.27
DBA/2J m 42.5 16.4   10 5.19 0.386 16.7, 66.7 1.86


  LEAST SQUARES MEANS (MODEL-ADJUSTED)
Strain Sex Mean SEM UpperCL LowerCL
129S6/SvEvTac m 29.16 2.9851 35.1054 23.2146
A/J m 13.9 3.1466 20.167 7.633
BALB/cByJ m 1.66 2.9851 7.6054 -4.2854
C3H/HeJ m 3.33 2.9851 9.2754 -2.6154
C57BL/6J m 1.9231 2.6181 7.1376 -3.2914
CBA/J m 0.0 3.3375 6.6472 -6.6472
DBA/1J m 17.8571 2.5229 22.8819 12.8323
DBA/2J m 42.51 2.9851 48.4554 36.5646




  GWAS USING LINEAR MIXED MODELS